Introducing VKVC Monolithic Insulating Joints, the ideal solution for Petrochemicals, Oil, Gas, LPG, and Water services. These joints offer versatility with various connecting configurations including Bevel ends, Flanged ends, and Threaded ends.
Insulating Joints are used on pipelines to provide electrical isolation to prevent corrosion. They provide current spreading on cathodic protection systems. They provide electrical separation between pipeline section and the adjoining neighbouring structures and pipelines.
Wherever practical, the VKVC insulating joint is intended to be installed above the ground, or in an inspection pit in dry conditions to limit the possibility of electrical bridging across the joint. It is intended to be girth welded between two pipeline sections.
VKVC Non-Intrusive Pig Signaller provides quick and easy pig detection of any pig moving between 0.01 and 20 meters/sec. It is Non-intrusive means less maintenance. non-corrosive, and no possibility of pipeline leak.
A small safe, permanent magnet or transmitter is installed on a pig is all it takes to put the GT-MAGNA-10 to work.
Remote signalling of the passage is easy with the built-in flashing LCD display and potential free relay contacts, which are normally open or close contacts and may use in conjunction with the existing SCADA system to integrate GT-MAGNA-10 into a pipeline control and signaling network. An optional array of 8 LED’s can be seen over distance.
BENEFITSADVANTAGES
No loss of integrity due to thermal expansion or ground stress as is common with flange isolation gasket kits.
In-factory tested hydrostatically and electrically, to 1.5 times their working pressure. Non destructive testing is also available.
Maintenance-free, reliable cathodic isolation of equipment in required isolation applications such as compressor stations.
No labor intensive, complicated installation procedure required as is the case with isolation gasket kits,
No inspection pits, vaults or maintenance needed – weld into place and direct bury – reliable, worry-free cathodic isolation.
Non-conductive epoxy coatings help prevent shorts, both internally and externally.
Isolation stray currents impressed on the pipe from exterior forces such as electrical transmission systems, earth currents and currents flowing from point to point.
Excellent bending and torsional resistance.
1 | Mounting | Overground / Underground |
---|---|---|
2 | Certifications | ATEX / PESO |
Note: VKVC offers certified engineers for offshore installation supervision, ensuring a seamless and efficient installation process
1 | Design Code | ASME Sec. VIII Div.1 for Body & ASME B31.8 for Pups |
---|---|---|
2 | Design Analysis | Finite Element Analysis |
3 | Material of Construction | ASTM A105/ ASTM A694/ ASTM A350LF2 (LTCS) |
4 | Seals | In – House Moulded HNBR/Fluro Elastomer/FFKM (AED certified) |
5 | Factory Acceptance Test | Seal Test Vacuum test & Air Test. |
Note: VKVC extends support with certified Engineers available for onshore installation supervision, guaranteeing a seamless implementation process.